Proizvodi
Tehnički predlog
SiSi / SiHF
Application:
For connection of mobile electrical appliances without mechanical stress at increased environmental temperatures, for example in steel-works, but also at low temperatures. Insulation and sheath are resistant against most oils, acids, lyes and oxidants. For fixed installation in mechanical protected conduits. For indoor and outdoor use.
| Conductor material: | Tinned copper | |
| Conductor construction: | Fine stranded, class 5 | |
| Insulation: | Silicone rubber | |
| Sheathing material: | Silicone rubber | |
| Flame retardant: | VDE 0482-332-1-2/IEC 60332-1 | |
| Halogen free: | DIN EN 50267/IEC 60754 | |
| Maximum temperature at conductor: | 180 °C | |
| Maximum operating temperature, fixed: | -60 / +180 °C | |
| Bending radius, fixed installation: | 5 x DA | |
| Bending radius, moved application: | 15 x DA | |
| Cable type: | SiHF-J | SiHF-O |
| Nominal voltage Uo: | 300 V | 300 V |
| Nominal voltage U: | 500 V | 500 V |
| Test voltage: | 2 kV | 2 kV |
| Core identification: | colours acc. VDE 0293 (HD 308); more than 5 cores: gn-ye + numbers |
colours acc. VDE 0293 (HD 308); more than 5 cores: gn-ye + numbers |