Proizvodi
Tehnički predlog
BayRail® A-2Y(L)2YB2Y

Application:
As a railway signalling cable, in railway control centres, surveillance systems and similar facilities, provided that the use of special signalling technology cables (e.g. PZB cables) is not stipulated.
Conductor diameter: | 0,9 | 1,4 |
Conductor resistance (pair of cores) Ω/km: | ≤ 56,6 | ≤ 23,4 |
Insulation resistance GΩxkm: | ≥ 10 | ≥ 10 |
Mutual capacitance at 800 Hz nF/km: | ≤ 45 | ≤ 45 |
For the central quad nF/km: | ≤ 50 | ≤ 50 |
Alternating voltage test 50 Hz: | ||
Core-core Veff | 2500 | 2500 |
Core-screen Veff | 2500 | 2500 |
Temperature ranges: | ||
During laying, installing °C | -10 do +60 | |
Before and after laying, installing °C | -40 do +60 | |
Additional information: A – Outdoor cable |